GAM 850 full automatic BGA visual inspection system
SMD parts are automatically placed to remove the quality instability of manual operation.
Using high efficiency top heater, the temperature can be adjusted from 500C-350C, and the removal / placement of SMD is fast and effective.
Dynamic and timely correction of thermal process temperature control time to ensure controllable temperature.
Special design bottom preheater matched with 4KW IR heater, carrying preventive plate bending mechanism, effectively prevent PCB processing process bad plate bending.
One body formed body with solid structure.
An accurate and fast three prism image segmentation para placement component system.
Provide instant temperature state (PROFILE) display.
PC BASE machine design, TOUCH PANEL interface operation easy to learn.
It can be matched with different heating tools, and can be applied to different size SMD components.
Product application
The electronic assembly processing plant resets the maintenance operation.
High stability multilayer PCB board, SMD assembly to assemble and remove heat flow reflow station.
You can place / remove PBGA, MBGA, CSP, PLCC, QFP, SOJ, MSP, SOP and so on SMD components.
It can be applied to 500mm x 600mm.
Product specification
A fixed PCB size X=300 Y=400
Standard of PCB anti bending support frame
PCB fixed frame left / right
Machine size (long * width * high) D620~920 W750, H660mm
Total power 2250W
Weight 80kg
Control operation system PC Base
Power demand AC220V + 10% single-phase Single phase
Air pressure flow
30L/min TOP=0.2millibar, Button=0.1millibar
Input pressure demand 5kg/Cm2
Operating system Window XP
Upper heater Air 600W Max.400 centigrade
Bottom heater Air 600W Max.300 centigrade
Pre heater IR400W 200V 425mm Max.250 C
Pre heating area (mm) 200x300
8 section of heating zone
Image corresponding system Prism with CCD Camera
Visual system magnification 300X
Visual image source LED
Screen LCD 17 "
Placement and adjustment of PCB mode semi-automatic
System placement error + 0.02mm
Temperature error of + 2 C
Placement of the extraction element size 5.0-50.0mm
Machine size D x W x H (mm) 1125 x 720 x 720 mm3
Weight 80kg
Three view